Textile Wastewater Treatment with PAC and PAM in Bangladesh

Time:2026-10-21

 

 

Project Overview

Textile and dyeing wastewater can be dark and turbid, with suspended solids and colloidal impurities that make solid–liquid separation challenging. A jar test was conducted to evaluate the combined use of Polyaluminium Chloride (PAC) and Anionic Polyacrylamide (APAM).

Treatment Challenges

  • Dark color and high turbidity
  • Suspended solids and colloidal impurities
  • Difficult floc formation and settling

Jar Test Procedure

  1. Add the textile wastewater sample to a beaker.
  2. Add 20 mL of 5% PAC solution and mix thoroughly.
  3. Add 10 mL of 0.1% APAM solution and mix thoroughly to promote floc formation.
  4. Stop stirring and allow the mixture to settle for solid–liquid separation.

Observed Results

Flocs formed during the test and settled after mixing stopped. The supernatant became clearer, while the solids gathered into settled sludge. The test demonstrated the coagulation and flocculation process using PAC and APAM.

Application Notes

The PAC and APAM volumes above are the amounts used in this beaker test. Since the wastewater sample volume and mixing conditions were not recorded, these quantities should not be treated as full-scale dosing recommendations. Actual dosage should be determined through jar testing with the site’s wastewater.

Recommended Treatment Sequence

PAC coagulation  →  APAM flocculation  →  Settling and solid–liquid separation

This process can be evaluated for textile and dyeing wastewater treatment. Treatment performance depends on wastewater characteristics, pH, dosage, and operating conditions.

Need Help with Textile Wastewater Treatment?

Contact TRONKI for PAC and PAM product selection guidance and jar test support.